Oxygen analyzer reduces emissions and saves fuel in combustion
31 January 2017
The XZR500 combustion control oxygen analyzer from Michell Instruments is designed to perform just one specialised function: to monitor the oxygen levels in combustion processes.
Its purpose is to determine the optimum amount of air needed for combustion, ensuring the fuel is used efficiently, potentially saving thousands of dollars.Too little oxygen means that more fuel is needed, while too much oxygen results in a fast burn, but produces a high level of emissions such as mono-nitrogen oxides (NOx), sulphur oxides (SOx), carbon dioxide (CO2) and carbon monoxide (CO). The XZR500 monitors the exhaust gas for excess oxygen ensuring that the conditions are kept close to stoichiometric (ideal) levels.
The XZR500 uses Michell’s Zirconium Oxide Oxygen Sensor, which has a metallic sealed reference (MSRS) to give long-term reliability. The combination of this type of sensor, placed in an isothermal oven within the analyzer (not the probe), negates the effects of varying, high temperatures as well as the corrosive nature of the gas. This also reduces time spent on maintenance: if a sensor needs replacement, this can be done within minutes without interrupting the process. The MSRS provides its own reference meaning a single calibration gas can be used.
The XZR500 has a control unit which can be placed at ground-level for convenience, a sensor head close-coupled to the stack for ease of installation and quick response and a variety of probe materials allowing a wide range of applications to be addressed with ease and confidence.
For most applications the probes use the Pitot effect to extract non-conditioned sample gas from the process to the sensor head and back to the flue. Placing the probe as close to the burner as possible gives accurate readings whereas installations further down the process have the risk of ambient air mixing with the sample and providing false readings. The XZR500 has ceramic probes capable of operating effectively in temperatures up to 1300°C.
Typical applications for the XZR500 include combustion efficiency for boilers, industrial waste incinerators and crematoria. When operated in extremely dirty applications, such as coal-fired power stations the XZR500 can be offered with a blow-back mechanism for increased reliability in readings and reduced manual intervention.
Other Press Releases By This Company
- 12/02/2024 - New Portable Dew-Point Hygrometer ensures compliance and quality in compressed air and specialized gases
- 20/06/2023 - Introducing the Multi-Channel Process Monitor
- 29/09/2022 - New Multi-Channel Control Unit combines trace moisture, moisture in liquids and trace oxygen
- 28/07/2022 - New Multi-Channel Control Unit combines trace moisture, moisture in liquids and trace oxygen
- 24/05/2022 - The latest cost-effective humidity calibration package from Process Sensing Technologies
- 20/04/2022 - New versatile dew-point hygrometer combines moisture and pressure readings
- 08/12/2021 - New process gas chromatograph for complete trace impurities analysis
- 02/12/2021 - What equipment do you need for reliable humidity calibrations?
- 02/11/2021 - Monitoring System: Machine to Machine (M2M) Integration
- 03/08/2021 - How accurate is your dew-point transmitter?
- 13/07/2021 - Introducing The new laboratory humidity reference standard: Michell S8000 -100
- 15/06/2021 - New accessories for gas chromatographs from LDetek prevent column degradation and control gas supply
- 07/06/2021 - Six Reasons to Consider Ceramic Metal Oxide Moisture Sensors for Your Process
- 18/05/2021 - How to install a dew-point transmitter for best accuracy
- 06/04/2021 - Trace impurities measurements from LDetek ensure quality of synthetic diamonds ‘grown’ in the lab
- 16/11/2020 - Affordable package for traceable humidity calibrations
- 19/10/2020 - LD8000 MultiGas Trace Impurities Analyzer for measurements in Lithium Ion Battery Manufacture
- 12/10/2020 - Trace moisture transmitter for UHP gases with smart digital connectivity
- 12/10/2020 - All-new portable hydrocarbon and water dew-point analyzer for natural gas quality
- 07/10/2020 - Michell’s Calibration Exchange Program is extended to the Easidew PRO XP Dew-Point Transmitter
- 05/06/2020 - New thermo-paramagnetic oxygen analyzer provides cost-effective quality control for oxygen generation
- 14/05/2020 - New lightweight binary gas analyzer for quality control of gases in safe areas
- 17/02/2020 - New lightweight oxygen analyzer for cost-effective quality control in safe-area applications
- 05/02/2020 - Fast-responding chilled mirror hygrometer selected for emissions control tests in China
- 15/01/2020 - New fast-responding dew-point transmitter controls efficiency of twin-column compressed air dryers
- 24/08/2018 - Combined humidity calibration ranges from Michell and Rotronic at IMEKO 2018
- 03/08/2018 - Michell moisture analyzer: proven efficacy for gas storage quality
- 05/07/2018 - QCM moisture analyzer for catalytic reforming processes – longer maintenance intervals despite an aggressive application
- 08/06/2018 - New configurable sampling system simplifies process moisture measurements
- 01/06/2018 - Discover the first ultra-low maintenance quart z crystal microbalance moisture analyzer
- 15/05/2018 - Complete range of high-precision hygrometers improved and relaunched
- 12/04/2018 - New Chilled Mirror Hygrometer from Michell with ALL-NEW sensor set to become the industry benchmark: Faster, more accurate and more rugged than ever.
- 27/03/2018 - New ATEX certification for AII’s portable oxygen analyzers
- 21/11/2017 - Reliable combustion control analysis for cremators: new application note
- 11/10/2017 - Cost-effective oxygen analyzer for marine maintenance
- 29/08/2017 - New oxygen analyzer targets combustion efficiency in boilers
- 03/08/2017 - Cost effective PPB oxygen analyzer for gas purity in semiconductor applications
- 17/07/2017 - Controlling the risk of explosions caused by dust: new case study
- 26/05/2017 - Michell Instruments – websites now in Spanish and Russian
- 15/05/2017 - Securing energy for the future: Michell’s OptiPEAK TDL600 used in research programme
- 10/03/2017 - Michell’s sensor exchange programme wins power station order
- 28/02/2017 - Trace oxygen analyzer ensures accuracy in cryogenic air separation
- 16/02/2017 - Cutting the costs of natural gas storage with optical moisture detection
- 13/01/2017 - High-precision trace moisture transmitter for high-purity gas applications
- 19/12/2016 - Versatile moisture measurements in wet and dry processes
- 28/11/2016 - Lightweight, ergonomic portable hygrometer for spot checks of natural gas
- 15/11/2016 - New 0.8% RH accuracy probe – order online
- 31/10/2016 - Compact chilled mirror hygrometer measures down to -90°C with no external cooling
- 21/10/2016 - New dedicated gas analyzer for hydrogen-cooled generators covers operation and maintenance needs
- 06/10/2016 - Compact portable hygrometer for convenient spot checks
- 20/09/2016 - Compact chilled mirror hygrometer gives high accuracy for reliable control of sintering processes
- 22/07/2016 - Built to last: a humidity probe for tough processes
- 24/05/2016 - Quick and easy – order Michell RH products online
- 24/05/2016 - New configuration and diagnostics tool from Michell Instruments
- 13/04/2016 - XGA301 Industrial Gas Analyzer ensures effectiveness of Glove Boxes
- 17/03/2016 - Michell introduces new relative humidity probe that hands control to the user
- 08/03/2016 - Michell’s process moisture analyzer approved for world-wide installation
- 11/02/2016 - Validation of humidity probes in-house is an affordable option with Michell’s new portable humidity validator
- 26/01/2016 - New options for Michell’s economical moisture sampling system
- 20/11/2015 - Not just a pretty face: redesigned S8000 Integrale from Michell offers faster response and improved functionality
- 16/11/2015 - New upgrade kits enable users to convert their transmitters into analyzers
- 03/11/2015 - Latest generation Quartz Crystal Microbalance moisture analyzer designed for easy installation and retrofit
- 28/09/2015 - As easy as changing a light bulb: fast, simple maintenance with increased accuracy for RH and temperature sensor
- 18/08/2015 - Humidity Calibration explained – free e-books available
- 06/08/2015 - Minimal maintenance means low-lifetime cost for Michell’s latest QCM analyzer
- 07/07/2015 - Michell Instruments awarded funding to develop energy-saving gas analyzer
- 24/06/2015 - The latest generation QCM moisture analyzer from Michell Instruments gives reliable readings at sub ppm levels
- 09/06/2015 - New Cost-Effective Analyzer from Michell Instruments Gives Maximum Flexibility
- 03/06/2015 - Michell’s rail industry approved moisture transmitter ensures safety for rolling stock braking systems
- 07/05/2015 - One simple system for moisture and hydrocarbon dew point in natural gas
- 16/04/2015 - Michell’s analyzers provide double safety assurance in subsea compression
- 16/03/2015 - The ‘right type’ of sensor: robust humidity sensor helps keep trains moving in cold weather
- 10/02/2015 - NEW Compact portable hygrometer with fast response
- 23/12/2014 - New, fast responding, moisture analyzer ensures quality of stored natural gas
- 04/12/2014 - Customised response from Michell future-proofs paint spraying facility
- 17/11/2014 - Michell Humidity Calibration Instruments Ensure Product Quality in Pharmaceutical Production
- 29/10/2014 - New moisture analyzer for natural gas gives unrivalled accuracy in changing gas streams
- 14/10/2014 - Simple, bench mount oxygen analyzer provides cost savings
- 10/10/2014 - Michell Instruments is East Cambridgeshire Business of the Year
- 10/10/2014 - High-speed portable hygrometer approved for explosive atmospheres in Brazil
- 06/10/2014 - Robust oxygen analyzer approved for hazardous area use in Brazil
- 03/10/2014 - Local display for easy operation on Michell’s new explosion-proof moisture transmitter
- 11/09/2014 - Interactive timeline celebrates 40 years of innovation
- 30/07/2014 - Chilled mirror hygrometers ensure safety of lithium-ion batteries in China
- 22/07/2014 - Promet Moisture Analyzer from Michell Instruments Plays a Key Role in Germany’s Sustainable Energy Plan.
- 10/07/2014 - Self-contained binary gas analyzer for fine control of hydrogen in heat treatment furnaces
- 29/05/2014 - New globally certified explosion proof dew-point transmitter provides universal solution
- 19/05/2014 - New RRS optical system gives Michell chilled mirror hygrometer exceptional response to trace moisture
- 25/04/2014 - IECEx certifications gain Michell world-wide approval for Exd analyzers
- 06/03/2014 - Advances in optical sensing technologies provide way forward for processing shale gas: new white paper available
- 10/02/2014 - Michell’s new quick connect option saves time and money in a tight spot
- 21/01/2014 - Compact, stand-alone chilled mirror hygrometer provides boost for small calibration labs
- 12/12/2013 - Ensuring safety of biogas production with Michell’s thermo-paramagnetic oxygen analyzer
- 05/12/2013 - Michell’s improved Optidew chilled mirror hygrometer exceeds the specifications set out in the Code of Federal Regulations (CFR) for Engine Testing
- 05/11/2013 - Robust oxygen analyzer for combustion control monitors its own “heartbeat”
- 08/10/2013 - Increased confidence in Hydrocarbon Dew Point measurements: new white paper available
- 08/10/2013 - Unique portable humidity calibrator from Michell provides 12 hours of use with no need for mains electricity
- 12/09/2008 - Moisture Control to Save Money