Company details for:

Atex Equipment Ltd

(0)

Littlehampton Business Centre,
10 East Street,
Littlehampton,
West Sussex,
BN17 6AW,
United Kingdom

Quick Links:

Products

Raychem trace heating cables - self regulating

Raychem trace heating cables - self regulating

Raychem self regulating trace heating cable automatically adjusts the power output to compensate for temperature changes. Raychem self regulating trace heating cables consist of two parallel conductors embedded in a heating core made of conductive polymer. Since the invention by Raychem of self regulating heat trace heating cable over 40 years ago, more than 500,000 km of Raychem self regulating heat trace heating cables are now installed successfully worldwide, offering proven and reliable electric heat trace heating systems. Some of the many benefits of self regulating heat trace heating cables are; • Easy installation as cables may be cut to length and be overlapped at valves or flanges • Uniform temperatures, as the heating cable senses and responds to actual conditions • Unconditional T-ratings as specified by European Norm EN 60079-30-1 • Maximum process temperatures, even when temperature controls fail • Operating voltages up to 277 V • Temperature maintenance up to 150°C • Circuit lengths up to 245 m Raychem self regulating heat trace heating system technology is available in BTV, QTVR, KTV, XTV or VPL heating tape ranges of products. Suitable for a diverse range of applications in construction for larger buildings, industry and hazardous area locations.
Raychem power limiting trace heating cable

Raychem power limiting trace heating cable

Raychem power limiting heating cables allow for higher exposure temperature and higher power output at elevated temperatures.Raychem power-limiting cables are parallel heaters formed by a coiled resistor alloy heating element wrapped around two parallel bus wires. At a fixed distance, the insulation is removed from the alternate bus wires to form a heating zone.The positive temperature coefficient effect (PTC) of the heating element reduces power output as ambient temperature increases. This effect allows the power-limiting cable to be overlapped by reducing the temperature of the heating element at the overlap points.Raychem power limiting cable can be used for freeze protection and process temperature maintenance requiring high power output and/or high temperature exposure. Raychem power limiting cables can provide process temperature maintenance up to 455°F (235°C) and can withstand exposure temperatures up to 500°F (260°C) with power off.
Raychem E-100-E trace heating end seal kit

Raychem E-100-E trace heating end seal kit

Raychem E-100-E End seal for termination of Raychem trace heating cable withiin ATEX hazardous area locations. The E-100-E is explosion proof and certfied for use in ATEX zone 1 and zone 2 hazardous areas. The Raychem E-100-E are accessible, re-entrable end seals that are pipe mounted and may be used with upto 100mm of insulation
Raychem JBS-100-E power connection junction box

Raychem JBS-100-E power connection junction box

The Raychem JBS-100-E trace heating junction box kit is designed to connect power to one Raychem BTV, QTVR, XTV, KTV or VPL industrial parallel heating cable. It is approved by PTB, FM and CSA, for use in hazardous locations.
Raychem JBU-100-E trace heating junction box

Raychem JBU-100-E trace heating junction box

The Raychem JBU-100-E modular junction box connects power to up to three BTV, QTVR, XTV, KTV or VPL heating cables. It can be directly mounted to a pipe or appropriate surface directly via a mounting bracket and is approved by PTB, FM and CSA for use in hazardous areas
Raychem C25-100 gland kit

Raychem C25-100 gland kit

The Raychem C25-100 connection kit is designed for terminating one Raychem BTV, QTVR, XTV, KTV or VPL industrial parallel circuit heat trace heating cable. It is approved by PTB use in ATEX hazardous locations.
Raychem C-150-E power connection

Raychem C-150-E power connection

Raychem C-150-E cold applied low profile connection kit. Designed to connect power 100-254 Vac, to a single Raychem BTV, QTVR, XTV or KTV heat trace heating cable. It can be directly mounted to a pipe and may withstand temperatures ranging from -50°C to +215°C and is approved by PTB for hazardous area use
Raychem E-03 end seal kit

Raychem E-03 end seal kit

Raychem E-03 trace heating heat shrink under insulation end seal kit. The Raychem E-03 is ATEX approved for use with BTV trace heating cable
Raychem EX-02 thermostat for trace heating systems

Raychem EX-02 thermostat for trace heating systems

The Raychem Raystat EX-02 is an ATEX certified explosion proof EEx d rated surface sensing thermostat to provide temperature control for electric heat trace heating (EHT) systems for Raychem BTV, QTVR, XTV & KTV heat trace heating cables. It is approved for use in ATEX hazardous areas. Benefits include, easy installation and commissioning, low cost installation and relative accurate control.
Raystat-EX-03 thermostat for trace heating systems

Raystat-EX-03 thermostat for trace heating systems

The Raystat EX-03 is and EEx e approved surface sensing thermostat to provide temperature control for electric heat tracing (EHT) systems with Raychem BTV, QTVR, XTV & KTV heating cables. It is approved for use in hazardous areas. Benefits include, easy installation and commissioning, low cost installation and relative accurate control.
Atex Zone 1, Compact Light , 1 x 8W 220...254V AC/DC.

Atex Zone 1, Compact Light , 1 x 8W 220...254V AC/DC.

CL series of compact fluorescent lights are explosion proof and suitable for use in Atex rated hazardous area zone 1, zone 2, zone 21 & zone 22, ingress protection rated IP66 and are suitable for wall or ceiling mounting. The CL-01 has a single electronic ballast, central locking via M8/SW13 socket spanner, suitable 1 x 8W Ø 16mm fluorescent bi-pin lamp.
Atex Zone 1, Fluorescent Light , 1 x 18W 110...254 AC/DC.

Atex Zone 1, Fluorescent Light , 1 x 18W 110...254 AC/DC.

FL series fluorescent fittings suitable for surface mount in Atex rated hazardous area zone 1, zone 21 & zone 22. Dual electronic ballasts, single end through wiring, earth continuity plates and single point locking, double sided lock with interlock switch to prevent operation when opened. 1 x 18 watt T8 fluorescent bi-pin lamp
ATX Legrand, Light , 1 x 36W 110...254V AC/DC

ATX Legrand, Light , 1 x 36W 110...254V AC/DC

ATX Light - FE series explosion proof fluorescent lights are suitable for use in Atex rated hazardous area zone 1, zone 2, zone 21 & zone 22, ingress protection rated IP66/67, suitable for wall or ceiling mounting, has an electronic multi-tap ballast, high impact resistance housing, hinged parabolic reflector and vibration resistant lamp holders suitable for 1 x 36W G13 fluorescent bi-pin lamp.
Atex Plug 32A 230V 3 Pin, Colour Blue

Atex Plug 32A 230V 3 Pin, Colour Blue

Explosion proof Atex plug, 32A 3 pin 200-25V 50/60Hz. ATEX certified explosion proof Ex rated flameproof plug for hazardous area zone 1, zone 21, zone 2 and zone 22. Laminated contacts, individually encapsulated flexibly embedded pins, motor switching capacity AC3 to VDE 0660 T107 (IEC 60 947-3), auxillary contact for control and signalling. Colour Blue
Atex, Socket 63A 200-250V 4 pin, max. 4 pole Colour Blue

Atex, Socket 63A 200-250V 4 pin, max. 4 pole Colour Blue

Socket, 63A 4 pin 200-250V 50/60Hz. ATEX certified EX explosion proof for use in hazardous areas zone 1, zone 21, zone 2 and zone 22. Laminated contacts, individually encapsulated flexibly embedded pins, large switch handles lockable in positions 0 and 1,motor switching capacity AC3 to VDE 0660 T107 (IEC 60 947-3), auxillary contact for control and signalling. Colour Blue
Atex Isolator Safety Switch, 10A 230V 3 Pole

Atex Isolator Safety Switch, 10A 230V 3 Pole

Isolator safety switch, 10A 3 pole 230V 50/60Hz for use in hazardous areas zone 1, zone 21, zone 2 and zone 22. motor switching capacity AC3 to DIN EN 60947-3, New easy install easy connect design, Connection terminals accessible from all sides, Labyrinth seal guarantees IP66 ingress protection. ATEX Certified
Atex Isolator Safety Switch, 20A 230V 3 Pole, Emergency Stop

Atex Isolator Safety Switch, 20A 230V 3 Pole, Emergency Stop

Isolator safety switch with emergency stop operator, 20A 3 pole 230V 50/60Hz for use in hazardous areas zone 1, zone 21, zone 2 and zone 22, motor switching capacity AC3 to DIN EN 60947-3, New easy install easy connect design, Connection terminals accessible from all sides, Labyrinth seal guarantees IP66 ingress protection. ATEX Certified
Start push button, ATEX zone 1

Start push button, ATEX zone 1

Explosion proof ATEX start push button control unit. 1 gang standard control station, Start (green I) push button c/w 1 x normally open contact, IP66 glass fibre reinforced polyester enclosure, 1 x M25 cable entry. Explosion protection: Ex III 2GD, Ingress protection: IP 65, Ambient temperature: -20 ºC .....+40ºC, Cable entries: 1 x M25
Start / Stop push button control station, ATEX zone 1

Start / Stop push button control station, ATEX zone 1

Explosion proof control unit - Start / stop push button, 2 gang, ATEX certified. Atex certified 2 gang standard control station, start (green I) and stop (red) pushbuttons c/w 1 x normally open or normally closed contact, IP65 glass fibre reinforced polyester enclosure. explosion protection: Ex II 2GD, Ingress protection: IP 66, Ambient temperature: -20 ºC .....+40ºC, Cable entries: 1 x M25
Trace Heating Design

Trace Heating Design

Trace heating system design - Design of trace heating systems in compliance with IEC 62395-2
Atex 168 LED light, Zone 1 110...254 AC

Atex 168 LED light, Zone 1 110...254 AC

168 LED, equivalent to 2 x 36W fluorescent. LL series LED explosion proof light fittings suitable for surface mount in Atex rated hazardous area zone 1, zone 2, zone 21 & zone 22. The LL series with LED were designed for direct 1 to 1 replacing of fluorescent light fittings. The equivalent luminous flux by lower energy consumption ensures an increase in efficiency of light systems
Atex 168 LED Emergency light, Zone 1 110...254 AC

Atex 168 LED Emergency light, Zone 1 110...254 AC

Emergency 168 LED light, equivalent to 2 x 36W fluorescent. LL series LED explosion proof light fitting suitable for surface mount in ATEX rated hazardous area zone 1, zone 2, zone 21 & zone 22. The LL series with LED were designed for direct 1 to 1 replacing of fluorescent light fittings. The equivalent luminous flux by lower energy consumption ensures increased in efficiency of light system
ATEX 68W LED Floodlight, Zone 1 110...254 AC

ATEX 68W LED Floodlight, Zone 1 110...254 AC

Floodlight 24 LED light, 68W output. The WL range is designed specifically for hazardous environments which require high performance, high reliability, White-Light illumination. Housed in Marine Grade aluminium with a toughened glass window, using field-proven, long-life LED technology, WL range is ATEX compliant and IECEx certified for all Zone 1 and Zone 2 applications and rated T4, T5 and T6
ATEX 37W LED Bulkhead Emergency, Zone 1 110...254 AC

ATEX 37W LED Bulkhead Emergency, Zone 1 110...254 AC

Bulkhead emergency 12 LED light, 37W, 3 hour duration. The XL range is designed for hazardous environments which require high performance, high reliability, white-Light illumination. Housed in Marine Grade aluminium with a toughened glass window, using field-proven, long-life LED technology, XL range is ATEX compliant and IECEx certified for all Zone 1 and Zone 2 applications and rated T4 and T5
ATEX LED Bay light 300W, Zone 1 110...254 AC

ATEX LED Bay light 300W, Zone 1 110...254 AC

Bay Light LED luminaire, ATEX and IEC Ex approved designed for Zone 1 hazardous environments which require high performance and high reliability white-Light illumination. Specifically, the Bay Light luminaire is designed for use in very high applications such as aircraft hangers or warehouses. Installations that require high quantities of light from a powerful ceiling mounted solution.

About us

Atex Equipment Ltd specialise in the design, supply and installation of Raychem trace heating. We are also suppliers of ATEX certified computing and handheld instruments & Ex explosion proof equipment for use in hazardous areas zone 1 and zone 2.

With over 30 years’ experience of trace heating, together with market leading product design of Raychem trace heating Atex Equipment is more than a supplier of Raychem trace heating. Atex Equipment can also provide advice on your surface heat management requirements.

Our extensive range of ATEX certified explosion proof hazardous area products include plugs and sockets, control stations, terminal enclosures, junction boxes, lights and lighting solutions, Raychem trace heating design, supply & installation, constant wattage, mineral isolated heating cables & ATEX handheld instruments & computers etc.

We are committed to product development and innovation on all Atex equipment, Raychem trace heating products and surface heating solutions. Atex Equipment exceed the latest requirements of IEC 62395-1 and IEC 62395-2 for guaranteed safety within hazardous area locations.

Atex Equipment Ltd specialise in the design, supply and installation of Raychem heat tracing. We are also suppliers of ATEX certified computing and handheld instruments & Ex explosion proof equipment for use in hazardous areas zone 1 and zone 2.

With over 30 years’ experience of trace heating, together with market leading product design of Raychem trace heating Atex Equipment is more than a supplier of Raychem trace heating. Atex Equipment can also provide advice on your surface heat management requirements.

Our extensive range of ATEX certified explosion proof hazardous area products include plugs and sockets, control stations, terminal enclosures, junction boxes, lights and lighting solutions, Raychem trace heating design, supply & installation, constant wattage, mineral isolated heating cables & ATEX handheld instruments & computers etc.

We are committed to product development and innovation on all Atex equipment, Raychem trace heating products and surface heating solutions. Atex Equipment exceed the latest requirements of IEC 62395-1 and IEC 62395-2 for guaranteed safety within hazardous area locations.

Our Raychem Trace Heating Cable products include Raychem trace heating cable - self regulating, Raychem series resistance trace heating cable, Raychem power limiting trace heating cable & Raychem constant wattage trace heating cable.

Our Raychem Trace Heating Component products include Trace Heating Junction Boxes, Power Connection, End Seal Kits, Splice, Tee, Insulation Entry Kits, Support Brackets, Accessories (Tapes, Labels, Glands).

Our Trace Heating Services include Inspection, Design & Installation.

Our ATEX Light products include ATEX LED Lights, ATEX Fluorescent Lights & Fluorescent Lights for Emergencies.

Our ATEX Plugs & Socket products include 16A Plug & Socket, 32A Plug & Socket & 63A Plug & Socket.

Our ATEX Isolators and ATEX Safety Switches are available in 10A-250A, 230V-690V.

Our ATEX Control Equipment are for hazardous areas zone 1 and zone 2.

Our ATX Explosion Proof lights are for use in hazardous areas zone 1, zone 2, zone 21 and zone 22.
Atex Equipment Ltd Website

Request a Quote