Company details for:
Medac Ltd
Alpha 319,
Chobham Business Centre,
Chobham,
Woking,
Surrey,
GU24 8JB,
United Kingdom
Quick Links:
Products
Air Sensitives
The analysis of air sensitive samples are subject to slightly longer turnaround times than those usually achieved; most analysis are performed within four working days. Minimum sample size depends on the analysis required.
CH&N Analysis
CH&N analysis is a cost-effective means of establishing sample purity on a wide range of sample types from volatiles to polymers. It is an essential tool in sample characterisation when used in conjunction with other techniques.
Same-day sample turnaround is available for extremely urgent requests, although most results are reported within two working days. Accuracy is ±0.30% absolute.
Minimum sample size is from 2 mg.
Sulfur Analysis
Sulfur analysis is a useful counterpart to other elemental analysis, such as C, H & N, and is available for most sample types. A same-day service can be arranged for particularly
urgent samples and our normal turnaround time is within two working days.
Accuracy is ±0.30% absolute and the detection limit is <0.1%. Minimum sample size is from 5 mg but also depends on the nature of the sample.
Please contact us for details.
Oxygen Analysis
The sample is weighed into a silver foil capsule and dropped into the reactor furnace which is maintained at 1060ºC, where the sample is pyrolised. Quantitative conversion of oxygen to carbon monoxide is achieved by a layer of nickel coated carbon. The pyrolised gas mixture then passes through an adsorption filter where halogenated compounds are retained. The gas mixture flows into the chromatographic column for separation of CO from N2, CH4 and H2. The CO is measured using a TCD which produces a signal proportional to the concentration. The instrument is calibrated with the analysis of known reference compounds.
Oxygen analysis can be carried out on most organic compounds although those containing quantities of fluorine can interfere with the process. Our normal turnaround time for oxygen analysis is within two working days but shorter turnaround times can be arranged for extremely urgent samples. Minimum sample size is 5 mg.
The Halogens
Normal turnaround time is within two working days and a same day service is available for extremely urgent samples. Accuracy is ±0.30% absolute.
Minimum sample size is 5 mg. Samples containing more than one halogen need to be analysed in a manner that avoids interference.
Metals (ICP)
A key to metals analysis is correct sample preparation. We have considerable experience of a wide range of preparation techniques and digestion methods for a variety of sample types.
Normal turnaround time is within two working days and a same day service can be arranged for extremely urgent samples.
Minimum sample size is from 5 mg, although larger quantities are required for trace analysis.
Anions (IC)
Detection limits depend on the sample type but, for aqueous solutions, analysis in the ppb (ng/ml) region are possible. Turnaround times for IC are normally within two working days and a same day service can be arranged for extremely urgent samples.
Minimum sample size is from 5 mg.
Moisture Determination
The coulometric KF titration is a version of the classical water determination method developed by Karl Fischer. In the coulometric titration the iodine needed is generated directly in the electrolyte by electrochemical means. The quantitative relationship between the electric charge and the amount of iodine being generated is used for high-precision dispensing of the iodine. As the coulometric KF method is an absolute determination no titer need be determined. The end point is indicated voltametrically by applying an alternating current of constant strength to a double platinum electrode. This results in a voltage difference between the Pt wires of the indicator electrode which is drastically lowered in the presence of minimal quantities of free iodine. This fact is used to determine the end point of the titration.
Residue on Ignition / Ashing Methods
Ashing is suitable for samples containing a significant amount of combustible organic material as the sample matrix and requires 1g of sample.
Other Services
Please contact us for details.
About us
We at Medac Ltd offer a unique range of testing and analysis services that have been highly recommended by our customers for many years, some of which include;
- Air Sensitives
- CH&N Analysis
- Sulfur Analysis
- Oxygen Analysis
- The Halogens
- Metals (ICP)
- Anions (IC)
- Moisture Determination
- Residue on Ignition / Ashing Methods
- Other Services
Priding ourselves on being the UK’s number one chemical consultancy service, we at Medac Ltd believe that elemental micro analysis is absolutely essential for any laboratory-based establishment. Our main focus as a company is to offer dedicated customer service by utilising the latest analytical technologies with our extensive amount of experience that has been gained over the years. We also work within academic institutions to test samples safely and professionally, ensuring maximum efficiency across all projects. We analysis solids, liquids, oils, organics and inorganics, organometallic samples, metals and plant materials, using our impressive amount of knowledge and skill.