Company details for:
Medem
Project House, 19 Dallimore Road,
Roundthorn Industrial Estate,
Manchester,
Lancashire,
M23 9NX,
United Kingdom
Quick Links:
Products
Gas Pressure Proving
Our proving systems are versatile and can be configured for various gas pressures up to 10 bar, with optional degreasing for use with oxygen supplies. Gas detection and ventilation interlocking depending on the intended application is included.
Commercial Kitchens VGPS-evo v4 Ventilation and Gas Proving System for Commercial Kitchens
SafeAir CM (GP) Gas Proving & Ventilation Interlocking for Commercial Kitchens
GPPS-evo v4 Laboratory Gas Pressure Proving System
SEC-Elite Programmable Multi-Line Gas Proving Detection System
SEC-B v5 Boiler Room Gas Pressure Proving System
Gas Detection & Monitoring Gas Detection & Monitoring Systems
Low and high level alerts with options for isolating a connected gas valve.
Multiple relay options are available for external signaling.
Thermal links, emergency stops, fire alarms can also be monitored.
Pro-Elite Modular, Programmable Gas Detection System
AGDS-Elite Modular, Programmable Gas Detection System
InAir v2 CO2 Monitoring System
SafeSpace V Gas Detection System with Valve Isolation
SafeSpace M Gas Detection System
Gas Detectors
Being a design and manufacturer we are always expanding our range of detectors, if you require something which isn't currently listed then please contact use as we can most likely quickly meet your requirements.
Sulfur Dioxide (SO2)
Gas detector
Designed for use with Medem systems
Propane C3H8 (LPG)
Detector location should be at lower levels (approx 20 cm to 30cm from the floor).
Detectors are set to alert at a pre-alarm level of 5% LEL and high-alarm of 10% LEL.
Propane is a colourless, flammable heavier than air gas.
Propane is commonly used as a fuel and is one of a group of liquefied petroleum gases.
ATEX Detectors
Can we supply a range of ATEX and IECEx detectors for use with our systems, please contact us with your requirements and we can guide you to the best solution for your application.
Ventilation Interlocking Systems
SafeAir (GP) Gas Proving and Ventilation Interlocking for Commercial Kitchens
It is designed for use within commercial kitchens, to aid sites in meeting BS6173:2020 and IGEM/UP19. It can also monitor for air quality when fitted with the required detectors with Carbon Dioxide PPM levels displayed on the LCD.
Gas proving must be fitted in any commercial kitchen which has appliances fitted without flame failure devices (FFD’s). As explained further in the article “why fit gas pressure proving in a commercial kitchen?” gas proving should be considered for the long-term benefit and safety of the site when considering other gas standards and that the majority of leaks identified are before the FFD’s.
CM2L-K Two Channel Current Monitor with LCD Display
Featuring an OLED display and simple button press learn feature makes the CM2L-K current monitor quick and simple to set-up.
CM2M-K Current Monitor
Fan load sensitivity range on each fan is 30 milliamps to 24 amps (max).
Features and Details:
There are 3 LED indications:
1x Green, for the 12-volt power to the CM2M-K.
2x Red, one for ‘Fan A’ and another for ‘Fan B’ load detection.
When the fans are switched on and the load is detected (installation instructions) the corresponding side’s NO/NC contact will close and the red LED will light, this will flash for the first 15 minutes after current detection and then become solid. The flashing LED helps us to identify a fan intermittently stalling.
About us
As a true design and electronics manufacturer, with a factory near Manchester Airport open for visits, we take pride in our products and the warranties we offer, especially when our systems are commissioned.
We offer a 5-year warranty on all Medem main panels and a 10-year warranty on all main panels and pressure sender units when commissioned by Medem.
Our Products Include:
Gas Pressure Proving Systems
Each Medem proving system utilises our patented differential gas pressure proving method, which is the only genuinely non-assumptive approach for conducting downstream integrity checks. These systems ensure accuracy and reliability by directly measuring pressure differentials during testing. Our proving systems are adaptable and can be configured for gas pressures up to 10 bar, with optional degreasing for oxygen supplies. They also include gas detection and ventilation interlocking features based on the specific application.
Gas Detection & Monitoring Systems
Our gas detection control systems are designed to monitor between 1 and 32 gas detectors of different types. They feature both low and high-level alerts, along with options to isolate a connected gas valve. Additionally, there are various relay options for external signalling, and the systems can also monitor thermal links, emergency stops, and fire alarms.
Gas Detectors
We offer a broad selection of gas detectors that cater to both common gases and specialised reactive gases, including options suitable for ATEX applications. As a design and manufacturing company, we continually expand our detector range. If you need a specific detector that isn’t currently listed, please reach out to us, as we can likely accommodate your requirements swiftly.
Ventilation Interlocking Systems
Our ventilation interlocking and gas proving systems are specifically designed for commercial kitchens to comply with BS6173 standards.
We are proud of our project portfolio across diverse industry sectors. Although we aim to highlight our control panel expertise through case studies, it’s important to recognise that a large part of our work remains confidential.
If you have any specific inquiries regarding our capabilities or would like to explore how we can address your unique needs, please feel free to reach out to us.