Company details for:
T&R Test Equipment Ltd
15-16 Woodbridge Meadows,
Guildford,
Surrey,
GU1 1BJ,
United Kingdom
Quick Links:
Products
50ADM-P Secondary Current Injection Test Set
100ADM-F Filter Unit
Improves timing accuracy when testing electro-mechanical relays
0.25A − 100A ranges
High overload capability
50/60Hz operating frequency
High efficiency
100ADM MK5
True RMS metering with single cycle capture
Auxiliary DC and AC output
Multi-function auto-ranging timing system
Current limit mode for fine control
Automatic mains voltage selection
Thermal and over-current protection
200ADM-P
True RMS metering with 1 cycle capture
Variable auxiliary ac voltage/ current output with phase shift
Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more
Variable auxiliary output 12-220Vdc
Multi-function auto-ranging timing system
Current limit mode for fine control
Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface
Automatic mains voltage selection
200A-3PH MK3
Accurate true RMS digital metering.
All outputs fully isolated.
Multi-function 1ms resolution timing system.
Auxiliary AC output.
Electronic over-current protection.
All test results can be stored to a USB memory key.
750ADM MK3
4V output*
16V 40A output for secondary injection
True RMS digital metering with single cycle capture
Multi-function timing system
Large back-lit liquid crystal display
Thermal and over-current protection
Automatic switch-off at end of test
Compact and portable
Automatic mains voltage selection*
Clear and simple user interface
PCU1-SP MK2
Multi-function digital timing system
Digital true RMS memory ammeter
Solid state switching
2000A and 5000A loading units
Three range outputs on loading units
Rugged, compact design
Optional trolley mounting of system
Secondary injection up to 100A
Auxiliary metering input
Direct reading CT ratio and polarity
CU-Ps
Multi-function digital timing system
5000A and 6000A loading units
Separate control and loading units
Secondary injection up to 100A
Direct reading CT ratio and polarity
True RMS metering with 1 cycle capture
Data storage to USB memory key including waveform & harmonics
USB keyboard interface
TPT9000 Transformer Polarity Tester
Compact and light
Easy to use, plug & play
Smart detection of incorrect connection
Proving unit included in the kit as standard
Fused lead sets included for user safety
Supplied in a protective case.
Long battery life
Built in battery monitor
DMO200
1-200Adc test current with <2.5% ripple
0.1μΩ resolution
mV, A, and m/μΩ displayed simultaneously
USB memory key for data storage
USB keyboard for comment entry
Pre-settable test current with three buttons to store user test currents
Large back-lit liquid crystal display
Universal supply voltage 90-264V
Supplied with 3m output lead set
Optional current clamp to allows testing of objects with both sides earthed
DMO600
10-600Adc test current with <2.5% ripple
0.1μΩ resolution
mV, A, and m/μΩ displayed simultaneously
USB memory key for data storage
USB keyboard for comment entry
Pre-settable test current with three buttons to store user test currents
Large back-lit liquid crystal display
Universal supply voltage 90-264V
Supplied with 3m output lead set
Optional current clamp to allows testing of objects with both sides earthed
KV5-100 MK3
Variable trip circuit.
12mA and 20-120mA.
Output voltage and current metering.
Visual and audible indication of test piece failure.
Compact lightweight instrument.
Burn feature giving 100mA maximum current on short circuit.
Key operated switch preventing unauthorised operation.
Complies with the testing requirements of BS1363.
KV30-40D MK4
0-30kV output voltage.
1.2kVA output capability.
Key operated supply switch to prevent unauthorised operation.
Dual overload protection.
Variable electronic trip − 10-110% of rated output.
Test timer
Voltage and current metering.
Zero-volt interlock.
External 24Vdc interlock circuit.
Visual indication of test piece failure.
PT30-10 MK3
10mA output capability.
Both voltage and current metered on HV outputs.
Automatic earth system for dumping capacitive loads.
HV output plug & socket system.
Key operated supply switch to prevent unauthorised operation.
Zero-volt interlock.
Visual indication of test piece failure.
Automatic mains voltage selection.
Z-OVR
Direct readout of cable Z & X
Phase angle display
Voltage up to 300V
Current up to 80A
Data storage to CSV file on USB memory key
Digital true RMS memory ammeter & voltmeter
Solid state switching
Rugged, compact design
LLT-11kV
Self powered operation
Indicates the presence of live voltage on circuits up to 11kV
Positive phasing test
High voltage measurement
Suitable for both dry and wet conditions
High quality fibreglass rod
Proving and repeater units
DC version available
High immunity to interference field
LLT-33kV
Self powered operation
Indicates the presence of live voltage on circuits up to 33kV
Positive phasing test
High voltage measurement
Suitable for both dry and wet conditions
High quality fibreglass rod
Proving and repeater units
DC version available
High immunity to interference field
HVD04/2B High Voltage Detecto
11/33kV Range and 2.5kV Threshold
Automatic alarming above threshold voltage as default
Easy to use and Lightweight (0.6kg)
Fast response time , less than 1 second
High Impact ABS body
Self test facility
Indoor/Outdoor use
-25°C to +55°C operating temp range
Shock & drop resistant
HVD10/2A High Voltage Detector
6.6/33kV Range and 1.2kV Threshold
Automatic alarming above threshold voltage as default
Easy to use and Lightweight (0.6kg)
Fast response time , less than 1 second
High Impact ABS body
Self test facility
Indoor/Outdoor use
-25°C to +55°C operating temp range
Shock & drop resistant
High Voltage Indicator
Can identify voltages as low as 200V
Can identify voltages as high as 15kV AC/DC
Suitable for checking busbars and switchgear enclosures
Ideal for use in cramped spaces
High immunity to interference fields
Proven resistor chain method of measurement
Safety limits are clearly marked
Features a handguard with a viewing window
Supplied with a proving unit with automatic battery check
Suitable for use inside and outside (provided it is used in dry conditions)
Can be used to check DC systems
Operating temperature: − 5˚C to + 50˚C
LLI-1500DC
Earth lead and clamp attached to long-length handle
Red LED indicators when voltage is detected
Loud 70dB alarm when voltage is detected
Audible indication: Buzzer, 3.1 kHz tone, modulated @ 2Hz
Can be used on third rail installations
Battery check function
Standard Threshold: 500V DC
Resistor Chain: 3MΩ
Operating time: 5 minutes nominal
WPC1000
High impact ABS body
Indoor/Outdoor use regardless of weather conditions
Automatic alarming above threshold voltage as default
11kV / 33kV Voltage Range
Range − 50m in air
−25°C to +55°C operating temp range
Shock and drop resistant
Various rod adaptors available
Easy access for battery replacement
Self Proving facility
Built in self-check facility
Operating Frequency − 433.9mHz
WPC2000
High impact ABS body
Indoor/Outdoor use regardless of weather conditions
Automatic alarming above threshold voltage as default
66kV / 132kV Voltage Range
Range − 50m in air
−25°C to +55°C operating temp range
Shock and drop resistant
Various rod adaptors available
Easy access for battery replacement
Self Proving facility
Built in self-check facility
Operating Frequency − 433.9mHz
HVD35/2A Dead Break Tester
Designed for use on capacitive test points of separable connectors
Able to test insulated polymetric cables in fused cable boxes
2/11kV Range and 100V Threshold
Automatic alarming above threshold voltage as default
Easy to use and Lightweight (0.6kg)
Fast response time , less than 1 second
High Impact ABS body
Self test facility
Indoor/Outdoor use
-25°C to +55°C operating temp range
Shock & drop resistant
HVD47/2B Dead Break Tester
Designed for use on capacitive test points of separable connectors
Up to 33kV Range and 600V Threshold
Automatic alarming above threshold voltage as default
Easy to use and Lightweight (0.6kg)
Fast response time , less than 1 second
High Impact ABS body
Self test facility
Indoor/Outdoor use
-25°C to +55°C operating temp range
Shock & drop resistant
About us
With a national and international customer base, our company has quickly developed a leading range of new and innovative products that are manually controlled and require little to no maintenance once installed. We have a number of DC cable test sets and AC flash testers that are each approved by our ISO9001, as well as relay test equipment, primary current injection systems and micro-ohmmeters.
Here at T & R, we have a team of experienced specialists who are dedicated to serving clients at all levels, no matter how large or small their project may be. We urge our customers to get in touch with our team and discuss any queries they may have, as this will result in a more efficient and better service. Some of our worldwide distributors include countries such as Australia, Brazil, Canada, Columbia, Cyprus, Czech Republic, Egypt, Germany, Hong Kong, India, Indonesia, Italy, Malaysia, Norway, Pakistan, Russia, Singapore, Spain and many more.
Over the years, our company has designed and developed high quality test equipment that is used primarily for transmission and distribution, power equipment manufacture and maintenance and commissioning. We as a company pride ourselves on our ability to build strong, durable products that are designed to last, meeting market demands quickly and efficiently.
We offer a re-calibration service for any of our bespoke products as well as a routine safety check, which is available to all customers who may be having difficulty applying the product to their applications. We will work closely with our customers to ensure that they receive outstanding service every time.