High power requirements vs. low power requirements on Sterilizers
16 June 2017
When it comes to powering an autoclave, there is a common misconception that a lower power requirement means lower power consumption. It is rarely the case.
For example, if you use a 3kW heater to boil three litres of water and it takes one hour, it would have used 3kW⋅h of power. In the same way, if you use a 1kW heater and it takes three hours to boil three litres of water, you have used 3kW⋅h of power – but it has taken a lot longer!This principal is the same on a sterilizer, particularly on square section units fitted with heated and cooling jackets. When starting an autoclave from cold, either at the beginning of the day or having completed a fluid cycle with jacket cooling, it is good practice to prepare the machine to effect a good sterilization cycle, i.e. heat the steam generator (if it’s cold), pressure vessel jacket, the load etc. It will take approximately the same amount of energy on all sterilizers of similar size to get the temperature from A to B, so if you use a higher power-rated sterilizer you get there much quicker than one fitted with a lower rated power supply.
Astell provides the best of both when we supply units fitted with our integral 48kW steam generator. This steam generator can supply lots of energy very quickly - to get the equipment up to temperature and ready to use (much quicker than low power units). Then, once the sterilizer jacket etc. is hot and up to pressure, Astell’s control system switches to a lower power requirement, the machine goes into economy mode, and now only uses 50% of its heating capacity as and when needed for the majority of most cycles that would be run.
When the machine is idle the steam generator can be programmed to switch off and only come back on when needed, to further save energy. Control of the steam generator is integrated in to Astell’s standard-fit colour touchscreen system.
At any time you can view the steam generator status, water levels high and low, running pressure, heater status etc. with one touch of the screen. Steam generator running pressure, blowdown, timed start and power usage are all fully programmable via the password protected touchscreen menus.
For further FREE no-obligation advice, or information on our range of autoclaves and steam generators please contact us.
Other Press Releases By This Company
- 15/05/2024 - Astell Ecofill Autoclaves: Still Leading the Way in Eco-Friendly Autoclaves After 25 Years
- 06/02/2024 - Astell at Analytica 2024: The home of cutting-edge laboratory technology
- 06/02/2024 - Compact benchtop autoclaves for the containment level 3 lab
- 06/02/2024 - Advancements in sustainable laboratory sterilization with Astell's eco-friendly benchtop autoclaves
- 06/02/2024 - Advancing eco-friendly sterilization: Astell's benchtop autoclaves
- 08/12/2023 - Advancing eco-friendly sterilization: Astell's benchtop Autoclaves
- 29/09/2022 - Protecting biodiversity in the Persian Gulf
- 02/08/2022 - All new at Achema'22
- 31/05/2022 - The green solution to laboratory wastewater sterilisation is black and white
- 07/03/2022 - The green solution to laboratory wastewater sterilisation is black and white.
- 15/09/2021 - Astell autoclaves are highly customisable, and each model is different, but their industry leading control-system is always the same.
- 03/08/2021 - Astell Scientific release a range of wastewater-sterilising sinks
- 14/10/2019 - Astell confirms Medica Trade Fair attendance
- 23/09/2019 - Thirteen year old Astell Autoclaves replaced like-for-like in SASA Upgrade
- 22/08/2019 - Astell supply four front loading autoclaves to Teesside University
- 22/08/2019 - Thirteen year old Astell autoclaves replaced like-for-like in SASA upgrade
- 10/06/2019 - Two chambers can be better than one
- 06/06/2019 - Astell Scientific launches new American website
- 09/05/2019 - Astell partner with Progressive Recovery, Inc. for USA
- 22/03/2019 - Autofill becomes Ecofill to reflect water savings on Benchtop and Compact autoclaves
- 15/01/2019 - Astell’s latest product guide features 8 new models
- 07/01/2019 - Astell introduces closed door drying benchtop autoclaves
- 24/07/2018 - Reduce water consumption with Astell’s Autofill benchtop autoclaves
- 08/06/2018 - Integrated hoist for Astell vertical autoclaves adds loading safety and versatility
- 08/06/2018 - Astell enjoys successful Scientific Laboratory Show 2018
- 07/06/2018 - Astell enjoys successful Scientific Laboratory Show 2018
- 16/04/2018 - Two 153 litre units are destined for a new laboratory facility in Oxfordshire.
- 15/02/2018 - Astell Scientific’s circular chamber autoclaves with sliding door offer potential cost and space savings
- 22/01/2018 - Astell Scientific launches dedicated Effluent Decontamination Systems website
- 04/01/2018 - Astell Scientific releases Remote Access /Network Connected autoclaves
- 07/12/2017 - Custom stainless steel autoclave for contact lens manufacturing
- 23/11/2017 - New video tutorials for Astell’s touchscreen controller
- 20/10/2017 - Astell's new autoclave software for FDA 21 CFR Part 11 standard
- 21/09/2017 - How to load an autoclave
- 14/08/2017 - Astell and JW Lees - A drinks industry autoclave case study
- 09/08/2017 - Tips for cleaning and maintaining your sterilizer
- 25/07/2017 - Astell releases new product catalogue
- 25/07/2017 - Enhanced efficiency for Astell SQUARE ECO autoclaves
- 27/06/2017 - Eco-friendly Benchtop autoclaves by Astell Scientific
- 16/06/2017 - Key questions to ask when buying a new autoclave - Power and installation requirements
- 15/05/2017 - Key questions to ask when buying a new autoclave - Sterilizer heating methods
- 11/05/2017 - Astell Scientific Benchtop autoclaves
- 04/05/2017 - Research-grade autoclaves by Astell Scientific
- 04/05/2017 - Double door, pass-through and double ended autoclaves
- 20/04/2017 - Key questions when buying a new autoclave - Circular or square chamber?
- 18/04/2017 - Key questions when buying a new autoclave - Circular or square chamber?
- 21/03/2017 - Expert advice for service and maintenance of your autoclave
- 13/03/2017 - Key questions when buying a new autoclave - Capacity and cycle time
- 10/03/2017 - Autoclaves then and now
- 20/02/2017 - Key questions when buying a new autoclave - What's the load?
- 10/02/2017 - USB port as standard on all Astell circular autoclaves
- 09/02/2017 - Autoclave validation and calibration services from Astell Scientific
- 20/01/2017 - Astell Helps the Fight Against Cancer
- 15/12/2016 - Astell Scientific’s new website compliments fresh product range and branding
- 10/11/2016 - Astell roll out latest colour touchscreen controllers for new autoclave range
- 20/10/2016 - A brand new look for Astell Scientific
- 22/09/2016 - Sterility Now with Astell Scientific
- 06/09/2016 - New autoclave range from Astell Scientific
- 11/03/2014 - No Drain? No Problem! – The Compact sterilizing solution that doesn’t need a Drain!
- 10/02/2014 - The Duaclave from Astell
- 03/05/2013 - Astell Goes Stateside
- 11/03/2013 - Can’t Touch This!
Released By
Related Websites
- https://www.astell.com/astell-support/topics/article/news/high-power-requirements-vs-low-power-requirements-on-sterilizers/?no_cache=1&cHash=921d56ecc7ed8f1984918204e0f1e6d1
- www.astell.com