Magnetrols' liquid level measurement solutions for Life Science and Food and Beverage industries
20 November 2009
World leading, global suppliers of high quality level and flow instrumentation, Magnetrol International are pleased to launch a range of liquid level instruments, dedicated to Life science and Food & Beverage industries.
This group of products further expands our extensive portfolio of high quality liquid level and flow products and allows us to further develop our successful entry into hygienic industries across Europe, the Middle East and Africa.The hygienic family of products have been designed and developed to the same exacting standards, for which all Magnetrol products are renowned worldwide and this group of products includes the industry leading Eclipse 705 Guided Wave Radar level transmitter, Echotel 960 series Ultrasonic liquid level switches and Thermatel TD/TG series Thermal Dispersion flow and level switches.
All Magnetrol hygienic products have been specifically designed to provide continuous reliability and repeatability, for even the most demanding of applications, and all hygienic products carry both 3A and EHEDG approval for use in applications that require the most stringent levels of cleanliness and they are ideally suited to both CIP and SIP cleaning regimes.
At the heart of the Magnetrol hygienic product family is the internationally acclaimed Eclipse 705 Guided Wave Radar. With over 6000 successful installations in hygienic applications around the world, the Eclipse has proven to be the level measurement instrument of choice for many globally recognised companies in the Food & Beverage, Biopharmaceutical and Pharmaceutical industries and with features, such as those shown below, it is easy to see why.
ECLIPSE 705 GUIDED WAVE RADAR FEATURES
• Two wire, 24vdc, loop powered transmitter for level, volume or interface measurement.
• Dry validation system allows the user to validate calibration on a purpose built test fixture in a workshop environment, without the need to fill and empty the vessel or remove the probe. This approach to validation offers our customers significant labour and material cost savings and process downtime when compared to traditional methods.
• Multiple bending allows the rod to be profiled to any vessel shape.
• Reliable and repeatable measurement is possible from the process connection right down to the probe tip allowing measurement from the first to the last drop and virtually eliminating the dead volume that cannot be measured.
• Simple loop tuning via PACTwareTM allows reliable and repeatable measurement even when vessel obstructions, such as, agitator blades and spray balls are within 6mm of the probe.
• Unaffected by changing process conditions such as vapour layers, foaming, surface agitation, bubbling or boiling, high fill and empty rates, varying dielectric and density changes that badly affect other technologies.
• Full ATEX hazardous area certification.
Other Press Releases By This Company
- 10/06/2015 - Magnetrol® Announces the “Just Can’t Stop a Magnetrol” Contest Magnetrol Level Switch Owners Could Win €500 and a New Level Switch
- 30/04/2015 - Magnetrol® announces the Thermatel® TA2 thermal mass flow meter with foundation fieldbus™ digital communications
- 15/08/2014 - Magnetrol’s Zele, Belgium Plant Receives BREEAM Interim Certificate for Design
- 13/08/2014 - Guided Wave Radar
- 30/05/2014 - Magnetrol announces new foundation fieldbus digital output communications for eclipse model 706 transmitter
- 20/02/2014 - Magnetrol introduces Polaristm Electromagnetic Flow Meters
- 20/01/2014 - Magnetrol® International opens new production facility in United Arab Emirates
- 08/10/2013 - Magnetrol Launches New Website and Expands to Accommodate Growth
- 23/09/2013 - New Senior Sales Engineer - John Squires
- 30/08/2013 - Magnetrol Publishes Heat Rate Reduction Kit
- 24/05/2013 - Magnetrol and APM announce a strategic partnership
- 06/03/2013 - Magnetrol International NV (Zele, Belgium) expands!
- 29/11/2012 - Eclipse Model 706 Transmitter
- 09/11/2012 - Level Control Performance
- 12/01/2012 - Eclipse®705 receives SIL3 - certificate from exida
- 27/10/2011 - Echotel® Model 962 Dual functionality in a single device
- 14/06/2011 - Thermatel® TD1/TD2 switches for high level alarm in natural gas filters
- 31/05/2011 - Trends Gazelles 2011
- 10/03/2011 - Thermatel® Enhanced Model TA2
- 09/02/2011 - Eclipse® 705 in critical applications
- 10/11/2010 - Magnetrol opens Representative Office in St Petersburg, Russia
- 08/06/2010 - Magnetrol International NV, for the second consecutive year one of the Trend “Gazelles” in Belgium.
- 19/04/2010 - Thermatel® TA2 Thermal Mass Flow Meter fromMagnetrol measures Greenhouse Gas.
- 16/04/2010 - Model R82, First rate, fully friendly,… less costly
- 08/01/2010 - New Echotel® 355 from Magnetrol is ultra smart and user friendly
- 03/09/2009 - Magnetrol in market first for Displacement Transmitter
- 16/04/2009 - Overfill-safe Eclipse® GWR probe from Magnetrol