Thermatel® TD1/TD2 switches for high level alarm in natural gas filters
14 June 2011
Thermatel TD1/TD2 switches are based on thermal dispersion technology.
The devices can easily be adjusted to detect flow (gases and liquids), level or liquid-liquid interface. With continuous diagnostics, automatic temperature compensation, narrow hysteresis and fast response time the Thermatel TD1/TD2 switches provide a new level of performance and reliability not found in previous switches.Gas compressor stations are mainly installed near extractions fields or underground storage facilities. A filter system is used to clean the extracted natural gas that will be brought into the compressor units. The Thermatel TD1/TD2 switch can be used for high level alarm in these natural gas filters.
On each filter a two level sensor (warning high level & alarm high level) is needed. For this application two TD1 switches can be utilized. The TD1 switch can operate under heavy conditions: typically for such a filter system high static pressure (~ 150 bar) and a rather specific medium (natural gas condensate in combination with sand & other waste).
However the TD1 switch can operate from -70 up to +450 °C and can handle pressures up to 410 bar. The TD1 uses a constant power to the sensor, meaning calibration can be performed easily and quickly. The built-in temperature compensation reduces the effect of sudden process temperature changes to a minimum and thus offering the benefit of a very fast response and highly repeatable operation. The switch also has a local error indication via a blinking LED.
The TD2 switch has all the features of the TD1 switch but can also send a mA error signal to the control room. This is very beneficial in critical service applications where the user needs to be assured the switch is operational. Another feature of the mA output is the possibility for trending and diagnostics providing a repeatable trend indication of the flow rate.
Other Press Releases By This Company
- 10/06/2015 - Magnetrol® Announces the “Just Can’t Stop a Magnetrol” Contest Magnetrol Level Switch Owners Could Win €500 and a New Level Switch
- 30/04/2015 - Magnetrol® announces the Thermatel® TA2 thermal mass flow meter with foundation fieldbus™ digital communications
- 15/08/2014 - Magnetrol’s Zele, Belgium Plant Receives BREEAM Interim Certificate for Design
- 13/08/2014 - Guided Wave Radar
- 30/05/2014 - Magnetrol announces new foundation fieldbus digital output communications for eclipse model 706 transmitter
- 20/02/2014 - Magnetrol introduces Polaristm Electromagnetic Flow Meters
- 20/01/2014 - Magnetrol® International opens new production facility in United Arab Emirates
- 08/10/2013 - Magnetrol Launches New Website and Expands to Accommodate Growth
- 23/09/2013 - New Senior Sales Engineer - John Squires
- 30/08/2013 - Magnetrol Publishes Heat Rate Reduction Kit
- 24/05/2013 - Magnetrol and APM announce a strategic partnership
- 06/03/2013 - Magnetrol International NV (Zele, Belgium) expands!
- 29/11/2012 - Eclipse Model 706 Transmitter
- 09/11/2012 - Level Control Performance
- 12/01/2012 - Eclipse®705 receives SIL3 - certificate from exida
- 27/10/2011 - Echotel® Model 962 Dual functionality in a single device
- 31/05/2011 - Trends Gazelles 2011
- 10/03/2011 - Thermatel® Enhanced Model TA2
- 09/02/2011 - Eclipse® 705 in critical applications
- 10/11/2010 - Magnetrol opens Representative Office in St Petersburg, Russia
- 08/06/2010 - Magnetrol International NV, for the second consecutive year one of the Trend “Gazelles” in Belgium.
- 19/04/2010 - Thermatel® TA2 Thermal Mass Flow Meter fromMagnetrol measures Greenhouse Gas.
- 16/04/2010 - Model R82, First rate, fully friendly,… less costly
- 08/01/2010 - New Echotel® 355 from Magnetrol is ultra smart and user friendly
- 20/11/2009 - Magnetrols' liquid level measurement solutions for Life Science and Food and Beverage industries
- 03/09/2009 - Magnetrol in market first for Displacement Transmitter
- 16/04/2009 - Overfill-safe Eclipse® GWR probe from Magnetrol