Mechanical Ventilation with Heat Recovery (MVHR) is increasingly used for controlled ventilation in new and existing buildings.
The tightness of buildings and lack of ventilation leads to problems such as mould and poor air quality, in addition to reduced comfort for occupants. High rise buildings with apartments and flats are a prime example of where MVHR units are used to effectively ventilate each room. Very often we will receive enquiries from domestic users who complain that their units are very noisy or seem ineffective, lots of these people confuse their MVHR with an air conditioner.We are no experts on finished heat recovery units, but we do work with MVHR manufacturers every day supplying industrial fans for use in these units. The fan is an integral part of these, and most, ventilation systems. We are experts in fans and fan integration so ask us any questions freely via email, or on the live chat, but in this article, we look at the difference between basic and quality MVHR systems.
A Basic MVHR system is the cheaper option and as expected, when compared with high quality systems, they do have a few downfalls. Minimal insulated housing reduces the cost of the units but can lead to heat loss, often cheaper filters are used too which can be ill fitting and allow dust to seep in and build up inside the ductwork, while blocked filters may contribute to poor ventilation disrupting the airflow and adding additional resistance causing an unbalance to the system.
These cheaper systems can often be quite noisy due to the integration of industrial fans producing vibration noise in operation, and poor insulation. Basic systems also tend to struggle in colder winter months and face an unbalance in the temperature distribution and reduced heat recovery. An unbalanced system can provoke excessive de-humidification, resulting in the air becoming too dry. Unfortunately, with cheaper heat recovery systems, where there is need for repairs, it is often the case that the entire system needs replacing.
Higher quality MVHR systems focus on a system that works well in all circumstances. They provide consistent and efficient ventilation with the use of constant volume fans that deliver a consistent airflow at all times regardless of resistance from blocked filters etc, always ensuring a reliable balance of heat removal and recirculation. Better systems will not struggle with seasonal variance as the correct heating components are put in place to prevent any imbalances. A superior quality system is well insulated with minimal noise output, the use of better industrial fans that have noise attenuation and produce less vibration are favourable in both domestic and commercial properties. Good quality systems are permanent fixtures, and parts can be repaired individually making them the more convenient and cost-effective option overall.
Most high-quality systems are Passivhaus certified meaning they are a suitable option for low energy buildings. The Passivhaus institute have set out their Passivhaus standard for new and existing buildings to be net-zero and provide proven approaches to achieving this. Its EnerPHit standards are for retrofitting existing systems in properties.
An MVHR system must reclaim enough heat to outweigh the energy consumption of the integrated fans and other components in the system. Popular industrial fans in most commercial MVHR units are the GDS range of EC forward curved fans from Ecofit. These are ideal for this application, and many other energy hungry units such as air curtains, due to their low energy consumption and built in constant volume electronics within the EC motor.
An important consideration when manufacturing MVHR systems is specific fan power, a parameter that quantifies the energy efficiency of fan air movement systems. A low figure indicates that a fan can deliver a given flow at a required pressure, while using as little electrical energy as possible. Fans have different SFP figures depending on the operating points, so this is not a constant figure and as such manufacturers will calculate the SFP based on their systems. Overall, the SFP should be as low as possible. Learn more about specific fan power here.
With constant demands to meet the latest sustainability targets and rising concerns about poor indoor air quality, it is important to understand what makes an efficient ventilation system and how to determine the best solution.
Certain factors need to be considered to ensure a MVHR system is efficient including the design, which is crucial for ensuring the whole area of the building will be covered. Correct installation is key, so it is advised to use a reputable supplier and installer for the project. Other crucial factors are decent quality ducting, correct placement of the intake terminal to avoid external pollution, and accessibility for maintenance. MVHR filters will also need to be changed in line with maintenance schedules to ensure optimal efficiency, and to further noise attenuate, silencers can also be fitted.
Other Press Releases By This Company
- 16/12/2024 - Dust Explosion Protection in Agricultural Silos
- 02/12/2024 - Achieve BREEAM Laboratory Credits with EC Fume Fans
- 12/11/2024 - Empowering Technical Buyers to Make Successful Decisions
- 25/10/2024 - Reduce Energy Consumption in Laboratories With EC Fume Fans
- 23/10/2024 - Axair Fans: Revolting for A Reason
- 10/10/2024 - Axair Fans Help Customers to Engineer Their Way out of the Skills Gap
- 02/10/2024 - Putting an End to Complacency in a Frustrated Marketplace
- 03/09/2024 - Reducing Time to Value: A Win For Customers
- 30/05/2024 - A New Approach in an Antiquated Industry
- 11/01/2024 - Advanced Digital Tools to Enhance Precision in Fan Specification for Fume Extraction Systems
- 15/11/2023 - BREEAM Indoor Air Quality with EC Plug Fans for Air Handling Units
- 07/09/2023 - ATEX S50 Polypropylene Fans for Fume Extraction Systems
- 04/05/2023 - Reducing Scope 2 Carbon Emissions with AHU Fan Upgrades
- 27/04/2023 - Understanding Corrosion Resistant C3, C4, C5 and CX Paint Grades
- 27/04/2023 - Energy Saving EC Forward Curved Fans for Air Curtains
- 27/03/2023 - ATEX Fans Crowned Winner of The Net Innovation Award 2023
- 24/03/2023 - ATEX Concepts: What is BS EN 14986:2017?
- 24/03/2023 - Zone Two ATEX Fans Designed to Equipment Category 3G
- 09/02/2023 - Corrosion Resistant Fans for Oxygen Rich Environments
- 25/01/2023 - The Complete School Fume Extraction Fan Kit
- 25/01/2023 - Centrifugal Blower Fans for Combustion Burning of Medical Waste
- 25/01/2023 - Zone One ATEX Fans for Category 2 Gas Environments
- 25/01/2023 - A Comprehensive Plug Fan Range
- 14/11/2022 - EC Fanwall Q&A for Engineers
- 24/10/2022 - The Role of the Industrial Blower Fan in Residual Waste to Energy Incineration
- 24/10/2022 - Corrosion Resistant Stainless Steel Fans – Robust & Hygienic
- 12/09/2022 - Combustible Dust Explosions in Industrial Processes
- 01/09/2022 - Exhaust Fans for Petrochemical Production in the Oil & Gas Industry
- 13/07/2022 - NIMUS Fans Improve Efficiency and Cost Reduction at UK Biomass Gas Site
- 28/06/2022 - Fans for Power Electronics Cooling
- 23/06/2022 - Replacing a Fan in a Fume Cupboard – Choosing the Right Plastic Fan
- 06/06/2022 - IIC Hydrogen Exhaust & Effective Battery Room Ventilation
- 01/06/2022 - Combustible Dust & Textile Industrial Fans
- 24/05/2022 - Ecofit Forward Curved Centrifugal Fans with AC or EC motors
- 09/05/2022 - New Launch: I-Series Backward Curved EC Plug Fans
- 05/05/2022 - Corrosive Fume Extraction Case Studies
- 21/04/2022 - Industrial Fans for Maximum Combustion in Waste Wood Renewable Energy Systems.
- 14/04/2022 - Transformer Cooling Fans
- 28/03/2022 - Air Measurement Tools for SprayBooth & Refinishing Applications
- 11/03/2022 - Industrial Fan Impellers & Fans for Spray Booth Ventilation
- 09/03/2022 - Axair Support the Development of Mobile Incineration Units
- 03/03/2022 - The advantages of multiple fans in parallel vs. a single fan in ventilation systems
- 03/12/2021 - Balanced Airflow in Heat Recovery Systems with Constant Volume Fans
- 11/08/2021 - High Performance Cooling for High Power Control Panels
- 19/07/2021 - A Fresh New Website & A Fresh New Team – How Axair Fans Has Changed
- 13/07/2021 - The Evolution of the Plug Fan
- 07/06/2021 - Extraction Fans for Indoor Swimming Pools & Chlorine Ventilation
- 18/05/2021 - Axair Partner with Buy Social Enterprise MSS-CKD
- 15/07/2020 - How to effectively protect your office spaces?
- 17/01/2020 - 5 Common Mistakes in Enclosure Cooling
- 03/01/2020 - Enclosure Cooling: Things to know about Airflow
- 14/11/2019 - Efficient Cooling Power Delivered to Rolling Stock Yard
- 15/10/2019 - The Importance of Chemical Storage Ventilation
- 24/09/2019 - 4 Ways to Cool a Cabinet
- 09/08/2019 - New Heights in Heat-Resistance: CLIBOS High Temperature Fan
- 04/07/2019 - Commercial Kitchen Extractor & Supply Air Fans
- 28/06/2019 - 4 Myths about Electrical Enclosures
- 03/05/2019 - Flexibility in Commercial Ventilation
- 11/04/2019 - Process Cooling in Factories
- 25/07/2017 - Alerting Live Enclosure Voltages with The Flash Signal Device
- 05/06/2017 - The Axair Group Launch The First ATEX IP68 Frame Axial Fan
- 24/03/2017 - Quiet fans score in laboratory environment
- 16/03/2017 - Understanding Fan Laws
- 17/02/2017 - Axair Donate to The Little Princess Trust
- 07/02/2017 - Selecting Industrial Fans For Biomass Applications
- 11/11/2016 - All About Smoke Control
- 25/10/2016 - New Product Release: Digital Electronic Speed Controller
- 06/10/2016 - Focus On Smoke, Pressurisation & Evacuation
- 09/09/2016 - Axair Fans Increase Company Portfolio
- 24/08/2016 - Getting To Know Axair Fans
- 22/07/2016 - Warehouse Ventilation | Centrifugal Roof Fans
- 02/06/2016 - Axair Fuel Fans For Efficient, Clean & Safe Biofuel Drying
- 18/04/2016 - Axair Fans UK Limited | Entering the World Of E-Commerce
- 12/04/2016 - Introduction to Mechanical Smoke Control
- 30/03/2016 - An Inland Of Revenue For AC Fans….
- 08/03/2016 - Axair Become Even More Responsive with A New Mobile Friendly Website..
- 14/01/2016 - “E” is for Energy Efficient - introducing the new E-Wheel
- 09/04/2013 - New ErP compliant Rosenberg fan
- 19/02/2013 - Rosenberg EC in-line duct fans from Axair
- 29/01/2013 - Inch blowers from Axair Fans
- 03/10/2012 - Axair offers the key to flexibility
- 06/08/2012 - Axair present new colour for enclosure cooling
- 24/02/2011 - Axairs' fans resist hazardous fumes
- 14/07/2010 - Axairs' high efficiency EC fans for installers
- 09/02/2010 - Kitchen extract fan now easy to clean